2.1.9. Compensation action
The compensation action button changes behavior based on the current compensation state.
- Learn starts measuring the selected compensation mode and updates a live learned correction.
- Lock stops learning and commits the current learned correction into compensation gain.
- Reset clears the stored compensation gain back to 0.00 dB.
While learning is active, the stored compensation value is not churned continuously. The live learned value is committed only when you press Lock.