3.1.17. Attack/Release

Attack sets how quickly gain falls; release sets how quickly it rises. Both default to 50 ms. Longer times smooth out gain changes but make Sync slower to reach the target.

Times can be set in samples, milliseconds, beats, or a ratio of the timing mode look-ahead. Beats use the BPM setting. Look-ahead units are relative to half the timing window; they produce an immediate response when low-latency timing removes the look-ahead.

Set attack and release in the full editor. Their values are kept when you switch to mini mode.

Actual size

Shown at its native size. Swipe or scroll to explore the full interface.